ROLL2BASKET service: set-up, settings and troubleshooting
From the DIP switches to the first embroidered tape: every commissioning step, the right T8 settings and the meaning of each error code – so your tape production is back up and running quickly.
ROLL2BASKET in action
Embroidering tape from the roll automatically – this is how the device looks on the machine.






How do you set up ROLL2BASKET?
For tape mode, activate the R2B device in the T8 under Tools, switch off the home function and enter the tape width and design size under the belt tape device settings. Then thread the tape, clamp it with the FRONT and REAR buttons and start with “Start 2”. Electrical connection and DIP switches are set by ZSK service during installation.
Step by step to a tensioned tape
Steps 1 to 4 are done once, or when switching between tubular and tape mode; steps 5 to 8 for every new tape.
- STEP 1
Check the DIP switches: DIP switch S4 or S5 on the Mini-Bus Controller must be on. In the T8, DIP switch S56 = 1 shows “belt tape device: present” and S73–S76 = 1100 the variant “vertical feed V3 (X axis)”. On the KSP Bus Controller, S9 is set to ON for SPRINT.
- STEP 2
Activate R2B: L2 Machine Settings → L2 Tools → tick the R2B device.
- STEP 3
Switch off the home function: L2 Machine Settings → R1 Operating Modes → deselect the home function with L1. It must be off before embroidering with ROLL2BASKET.
- STEP 4
Tape width and design size: L2 Machine Settings → R2 Band Sticking Device. Example from the ZSK Quick Guide: tape width 30 mm, design size 120 mm. Select the belt tape device application when loading the design.
- STEP 5
Prepare the tape: Switch the machine off. For tapes 10–40 mm wide, fit the presser foot for narrow tapes, adjust the guides to the tape width, set a pressing angle of 65–85° and a pre-tensioning force of 0.6–1.5 kg. Pull out 1–2 m: the tape must run evenly and must not slip out from under the presser foot.
- STEP 6
Align hoop and device: Fit the pneumatic hoop in the tubular holder, switch the machine on and select tape mode in the T8. Move the hoop along the X axis until the needle hole is centred on the tape. Fix the tape control device and connect compressed air (6 bar).
- STEP 7
Thread the tape: Press the ZSK button for manual mode and release the tape at the front and rear – both LEDs top right are off and the clamping cylinders are open. Place the tape end between the pulling rollers, press forward rotation and pull the tape until about 30 cm hangs free below the rollers.
- STEP 8
Clamp and start: Reset compensation to 0 (hold “−” until the LED flashes). FRONT clamps the tape at the front, REAR draws and tensions it at the rear. Choose the feed mode, set ZSK to automatic and press “Start 2” once – the tape is tensioned and both LEDs top right light up.

S56 = 1 tells the control system the belt tape device is fitted. Save changes with “save settings”.

Use an electronic balance to check the pre-tensioning force of 0.6 to 1.5 kg. Only the presser foot may press on the tape.

When the FRONT and REAR LEDs are lit, both clamping cylinders are closed and the tape is ready to embroider.
Every step in pictures
The photos from the operating and installation manual and the Quick Guide show the steps above in detail – from the scope of supply to the tensioned tape. They follow the order of the manual.
Scope of supply and set-up
What comes with ROLL2BASKET and how the hoop, tape control device and tape coil sit on the machine.






Quick Guide: DIP switches, threading, clamping cylinders
The pictures from the ZSK Quick Guide for steps 1, 7 and 8.





Preparing the hoop and laying the tape
Presser foot, guides, pressing angle and pre-tension – for every new tape width, thickness or structure.













Switch on, align, connect air
Centre the hoop on the tape, fix the tape control device and connect 6 bar compressed air.






Threading, clamping and starting
Using the ROLL2BASKET control panel: release, thread, clamp, choose the feed and start with “Start 2”.














Which feed suits your tape?
After each design, the tape control device advances the tape by the set tape length. Choose the feed mode by thickness and width.
| Tape | Feed | Indicator / note |
|---|---|---|
| up to 2 mm or non-rigid, narrower than 50 mm | two-way feed (forward and reverse transport) | LED under the double-headed arrow; close the acrylic cover |
| thicker than 2 mm or rigid, or wider than 50 mm | one-way feed | LED under the right arrow; increase the roller spring tension |
- Load the design: the embroidery length must not exceed 200 mm. Select the origin point and trace the outline (“Design Range”), then start embroidering.
- Usable width: tape width minus 2 × 4 mm safety margin. Optionally the T8 stitches a separation mark to make cutting easier; overlap mode allows continuous designs without a visible join.
- Compensate the repeat: if a gap forms between two elements, hold “+” until the LED flashes and set steps of 0.2 mm each (1.0 mm = 5 steps). If elements overlap, the tape is too stretchy or the pre-tensioning force is above 1.5 kg.
- Design layout: align the centre lines of design and tape, embroider along the tape from bottom to top. For tapes 0.2–0.35 mm thick, use a stitch density greater than 0.7 mm. Do not modify or optimise designs when loading, or the stitch sequence may be disrupted.
Embroidering, repeats and design layout
Load the design, check continuous designs and compensate gaps – with examples of designs suited to tape.









Take-up station
The finished tape drops into the basket or is wound up on the optional take-up station. How to set it up and tension the tape: plug the embroidery machine into the take-up station and the station into the mains, align the tape at right angles to its axle and set the coil disc to the tape width.





Keep the tape running true
- Daily: visually check the device’s electrical connections and insulation.
- Before cleaning and maintenance: switch the embroidery machine off, unplug it and vent the compressed air.
- Do not clean control components with compressed air.
- Check the air supply: 6 bar at the pressure reducer, input pressure above 6 bar – low air pressure is one possible cause of error E2.
- When changing tape: readjust presser foot, guides and pre-tension and repeat the pull test – an incorrectly adjusted presser foot causes embroidery faults.
Sensor checks – for trained staff
Hall sensor of the tension lever: in manual mode, hold “+” and “−” for at least 4 s until the display flashes slowly. At rest it reads 0, with the lever fully pressed 7–9. Automatic calibration is started with the key combinations “−”, “1”, “2” and “+”, “1”, “2” as described in the manual.
Force sensor: hold “+” and “−” for at least 6 s until the display flashes rapidly. Released it reads 8–9; with about 1 kg of force on the lever it reads 4–3 – the sensor is OK.
Calibration and sensor test in pictures
The picture sequence for the sensor checks above – for trained staff or ZSK Service.









ROLL2BASKET error messages
The 7-segment display alternates between “E” and the error code. Reset with a short press on the ZSK button; if the error cannot be reset, switch the embroidery machine off and on again.
| Message | Cause | Remedy |
|---|---|---|
| E1 | Stepper motor driver overload | Check the stepper motor connection. An internal electronic fault is possible – contact ZSK service. |
| E2 | Tape cannot be tensioned; end of tape reached | Check the tape is laid correctly, check the force sensor, check the pulling rollers are not slipping, check the air pressure, check the tape is clamped by the front clamp. |
| E3 | No signal from the tension lever Hall sensor when releasing the tape; tension lever cannot reach the middle position | Check the tension lever for jamming and the return spring, check the Hall sensor signal range, check the magnet position relative to the Hall sensor. |
| E4 | No signal from the Hall sensor when tensioning the tape; tension lever not in the middle position | Check the tape is laid correctly, check the tension lever for jamming, check the Hall sensor signal range and the magnet position. |
| E8 | Hall sensor calibration values stored in the EEPROM below the permitted range | Check signal range and magnet position, recalibrate the magnet. |
| E9 | Hall sensor calibration values stored in the EEPROM above the permitted range | Check signal range and magnet position, recalibrate the magnet. |
Installation by ZSK Service – picture documentation
ZSK Service sets up the electrical connection, DIP switches, compressed air and tape holder during installation. The picture sequences from the installation manual show every step – for information and for technicians. Only work inside the machine with the machine switched off and the mains plug pulled. Depending on the machine, the connection is made via the KSP-10 adapter board in the embroidery head or the KSP Bus Controller mini on the MCP31 board.
Electrical connection with KSP-10 adapter board32 pictures: open the head cover, fit the adapter, flat cable, power, jump stitch magnet, cable to X9
































Electrical connection with KSP Bus Controller mini (MCP31)15 pictures: back cover, connectors X3/X6, DIP switches S9/S10, “HWOT” LED















Compressed air connection10 pictures: pressure reducer, tube, coloured tubes, setting 6 bar










Fitting the tape holder10 pictures: holder, guide rail axle, coil cheeks, tape coil, fixing ring










Brief and binding
- Only trained personnel may work on the machine with devices fitted.
- No fingers in the embroidery zone during operation; keep fingers away from the pulling rollers and close the acrylic cover.
- Work on the tape path only with the machine switched off or ROLL2BASKET in manual mode.
- Do not operate with wet hands or in rooms with humidity above 95 %.
- Use the device only for its intended purpose and in a technically safe condition.
Manual and software
The full user’s manual for the belt tape device, with mechanical, electrical and pneumatic installation, and the Quick Guide are available on request from ZSK service. The latest T8 software is in the download area.
More on ROLL2BASKET and the T8

Tape stopped? We will help.
Tell us the machine type, serial number and the error code shown – ZSK service will get back to you with the right solution.
Questions about ROLL2BASKET service
Short answers for operators and technicians. Missing your question? ZSK service helps personally.
Where do I activate ROLL2BASKET in the T8?
Go to L2 Machine Settings → L2 Tools and tick the R2B device. Then switch off the home function with L1 under R1 Operating Modes, and enter the tape width and design size under R2 Band Sticking Device, for example 30 mm and 120 mm.
Which DIP switches does ROLL2BASKET need?
According to the ZSK Quick Guide, DIP switch S4 or S5 on the Mini-Bus Controller must be on. In the T8, S56 is set to 1 (“belt tape device present”) and S73–S76 to 1100 (“vertical feed V3, X axis”). These settings are normally made by ZSK service during installation.
How do I open the clamping cylinders?
Press the ZSK button on the ROLL2BASKET control panel to switch to manual mode and release the tape at the front and rear until both LEDs top right are off. To embroider, close them with FRONT and REAR, set ZSK to automatic and press “Start 2” once.
What does error E2 mean?
E2 means the tape cannot be tensioned or the end of the tape has been reached. Check how the tape is laid, the force sensor, whether the pulling rollers are slipping, the air pressure and whether the tape is clamped at the front. Then reset the error with a short press on the ZSK button.
When do I choose one-way or two-way feed?
Use one-way feed for tapes thicker than 2 mm, rigid tapes and tapes wider than 50 mm. Use two-way feed – forward and reverse transport – for tapes up to 2 mm or non-rigid tapes narrower than 50 mm. The LED under the right arrow or under the double-headed arrow shows the selected mode.
How do I get the manual for the belt tape device?
ZSK service provides the user’s manual and the Quick Guide on request. Use the service request form and state the machine type and serial number. The latest T8 software is in the download area of the website.